GE Data Sheet 20A Digital MicroDLynxTM: Non-Isolated DC-DC Power Modules 3Vdc -14.4Vdc input; 0.45Vdc to 5.5Vdc output; 20A Output Current Features RoHS Compliant Applications Compliant to RoHS II EU "Directive 2011/65/EU" Compliant to RoHS EU Directive 2011/65/EU under exemption 7b (Lead solder exemption). Exemption 7b will expire after June 1, 2016 at which time this produc twill no longer be RoHS compliant (non-Z versions) Compatible in a Pb-free or SnPb reflow environment (Z versions) Compliant to IPC-9592 (September 2008), Category 2, Class II DOSA based Wide Input voltage range (3Vdc-14.4Vdc) Output voltage programmable from 0.45Vdc to 5.5Vdc via external resistor and PMBusTM # Digital interface through the PMBusTM # protocol Tunable LoopTM to optimize dynamic output voltage response Flexible output voltage sequencing EZ-SEQUENCE Power Good signal Distributed power architectures Intermediate bus voltage applications Telecommunications equipment Fixed switching frequency with capability of external synchronization Output over current protection (non-latching) Servers and storage applications Over temperature protection Networking equipment Remote On/Off Industrial equipment Ability to sink and source current Cost efficient open frame design Small size: 20.32 mm x 11.43 mm x 8.5 mm (0.8 in x 0.45 in x 0.334 in) Wide operating temperature range [-40C to 105C (Ruggedized: -D), 85C(Regular)] Vin+ VIN PGOOD Vout+ VOUT VS+ RTUNE MODULE SEQ Cin CLK TRIM DATA ADDR0 SMBALRT# ADDR1 ON/OFF GND CTUNE Co RTrim RADDR1 RADDR0 UL* 60950-1 2nd Ed. Recognized, CSA C22.2 No. 60950-1-07 Certified, and VDE (EN60950-1 2nd Ed.) Licensed ISO** 9001 and ISO 14001 certified manufacturing facilities SIG_GND SYNC GND VS- Description The 20A Digital MicroDLynxTM power modules are non-isolated dc-dc converters that can deliver up to 20A of output current. These modules operate over a wide range of input voltage (VIN = 3Vdc-14.4Vdc) and provide a precisely regulated output voltage from 0.6Vdc to 5.5Vdc, programmable via an external resistor and PMBus TM control. Features include a digital interface using the PMBusTM protocol, remote On/Off, adjustable output voltage, over current and over temperature protection. The PMBus TM # interface supports a range of commands to both control and monitor the module. The module also includes the Tunable Loop TM feature that allows the user to optimize the dynamic response of the converter to match the load with reduced amount of output capacitance leading to savings on cost and PWB area. * UL is a registered trademark of Underwriters Laboratories, Inc. CSA is a registered trademark of Canadian Standards Association. VDE is a trademark of Verband Deutscher Elektrotechniker e.V. ** ISO is a registered trademark of the International Organization of Standards # The PMBus name and logo are registered trademarks of the System Management Interface Forum (SMIF) September 7, 2017 (c)2017 General Electric Company. All rights reserved. GE Data Sheet 20A Digital MicroDLynxTM: Non-Isolated DC-DC Power Modules 3Vdc -14.4Vdc input; 0.45Vdc to 5.5Vdc output; 20A Output Current Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability. Parameter Input Voltage Device Symbol Min Max Unit All VIN -0.3 15 V 7 V Continuous SEQ, SYNC, VS+ All CLK, DATA, SMBALERT# All 3.6 V Operating Ambient Temperature All TA -40 105 C All Tstg -55 125 C (see Thermal Considerations section) Storage Temperature Electrical Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. Parameter Device Symbol Min Typ Max Unit Operating Input Voltage All VIN 3 14.4 Vdc Maximum Input Current All IIN,max 19 Adc (VIN=3V to 14V, IO=IO, max ) VO,set = 0.6 Vdc VO,set = 5Vdc Input No Load Current (VIN = 12Vdc, IO = 0, module enabled) Input Stand-by Current (VIN = 12Vdc, module disabled) Inrush Transient Input Reflected Ripple Current, peak-to-peak (5Hz to 20MHz, 1H source impedance; VIN =0 to 14V, IO= IOmax ; See Test Configurations) Input Ripple Rejection (120Hz) September 7, 2017 IIN,No load 69 mA IIN,No load 134 mA All IIN,stand-by 16.4 mA All I2t 1 A2s All 50 mAp-p All -64 dB (c)2017 General Electric Company. All rights reserved. Page 2 GE Data Sheet 20A Digital MicroDLynxTM: Non-Isolated DC-DC Power Modules 3Vdc -14.4Vdc input; 0.45Vdc to 5.5Vdc output; 20A Output Current Electrical Specifications (continued) Min All Symbo l VO, set All VO, set -3.0 All VO 0.6 PMBus Adjustable Output Voltage Range All VO,adj -25 PMBus Output Voltage Adjustment Step Size All Remote Sense Range All Parameter Output Voltage Set-point (with 0.1% tolerance for external resistor used to set output voltage) Output Voltage (Over all operating input voltage, resistive load, and temperature conditions until end of life) Adjustment Range (selected by an external resistor) (Some output voltages may not be possible depending on the input voltage - see Feature Descriptions Section) Device Typ -1.0 0 Max Unit +1.0 % VO, set +3.0 % VO, set 5.5 Vdc +25 %VO,set 0.4 %VO,set 0.5 Vdc 0.27 0.4 % VO, set Output Regulation (for VO 2.5Vdc) Line (VIN=VIN, min to VIN, max) All 0.17 Load (IO=IO, min to IO, max) All 10 mV Line (VIN=VIN, min to VIN, max) All 5 mV Load (IO=IO, min to IO, max) All 10 mV Temperature (Tref=TA, min to TA, max) All 0.4 % VO, set 50 100 mVpk-pk 20 38 mVrms 2x47 F Output Regulation (for VO < 2.5Vdc) Output Ripple and Noise on nominal output (VIN=VIN, nom and IO=IO, min to IO, max Co = 0.1F // 22 F ceramic capacitors) Peak-to-Peak (5Hz to 20MHz bandwidth) RMS (5Hz to 20MHz bandwidth) External All All Capacitance1 Without the Tunable LoopTM All CO, max 2x47 ESR 0.15 m All CO, max 2x47 1000 F ESR 10 m All CO, max 2x47 10000 F All Io 0 20 Adc All IO, lim 110 130 150 % Io,max All IO, s/c 1.4 2.5 3.6 Arms ESR 1 m With the Tunable LoopTM Output Current (in either sink or source mode) Output Current Limit Inception (Hiccup Mode) (current limit does not operate in sink mode) Output Short-Circuit Current (VO250mV) ( Hiccup Mode ) Efficiency VO,set = 0.6Vdc 76.0 79.1 % VIN= 12Vdc, TA=25C VO, set = 1.2Vdc 84.3 87.1 % IO=IO, max , VO= VO,set VO,set = 1.8Vdc 87.2 90.4 % VO,set = 2.5Vdc 90.3 92.6 % VO,set = 3.3Vdc 91.4 93.8 % VO,set = 5.0Vdc 92.8 95.2 % All fsw 475 500 Switching Frequency 525 kHz 1 External capacitors may require using the new Tunable LoopTM feature to ensure that the module is stable as well as getting the best transient response. See the Tunable LoopTM section for details. September 7, 2017 (c)2017 General Electric Company. All rights reserved. Page 3 GE Data Sheet 20A Digital MicroDLynxTM: Non-Isolated DC-DC Power Modules 3Vdc -14.4Vdc input; 0.45Vdc to 5.5Vdc output; 20A Output Current Electrical Specifications (continued) Parameter Device Frequency Synchronization Symbol Min Typ Max Unit 600 kHz All Synchronization Frequency Range All High-Level Input Voltage All 425 Low-Level Input Voltage All VIL 0.4 V Input Current, SYNC All ISYNC 100 nA Minimum Pulse Width, SYNC All tSYNC 100 ns Maximum SYNC rise time All tSYNC_SH 100 ns Device Min VIH 2.0 V General Specifications Parameter Calculated MTBF (IO=0.8IO, max, TA=40C) Telecordia Issue 2 Method 1 Case 3 Typ All 15,455,614 4.086 (0.14) Weight Max 4.54 (0.16) Unit Hours 4.994 (0.18) g (oz.) Feature Specifications Unless otherwise indicated, specifications apply overall operating input voltage, resistive load, and temperature conditions. See Feature Descriptions for additional information. Parameter Device Symbol Input High Current All IIH Input High Voltage All VIH Min Typ Max Unit 1 mA 2 VIN,max V On/Off Signal Interface (VIN=VIN, min to VIN, max ; open collector or equivalent, Signal referenced to GND) Device code with suffix "4" - Positive Logic (See Ordering Information) Logic High (Module ON) Logic Low (Module OFF) Input Low Current All IIL 1 mA Input Low Voltage All VIL -0.2 0.6 V Device Code with no suffix - Negative Logic (See Ordering Information) (On/OFF pin is open collector/drain logic input with external pull-up resistor; signal referenced to GND) Logic High (Module OFF) Input High Current All IIH 1 mA Input High Voltage All VIH 2 VIN, max Vdc Logic Low (Module ON) Input low Current All IIL 10 A Input Low Voltage All VIL -0.2 0.6 Vdc September 7, 2017 (c)2017 General Electric Company. All rights reserved. Page 4 GE Data Sheet 20A Digital MicroDLynxTM: Non-Isolated DC-DC Power Modules 3Vdc -14.4Vdc input; 0.45Vdc to 5.5Vdc output; 20A Output Current Feature Specifications (cont.) Parameter Device Symbol Min Typ Max Units All Tdelay 0.8 1.1 1.7 msec All Tdelay 600 700 1800 sec All Trise 1.2 1.5 2.7 msec 3.0 % VO, set Turn-On Delay and Rise Times (VIN=VIN, nom, IO=IO, max , VO to within 1% of steady state) Case 1: On/Off input is enabled and then input power is applied (delay from instant at which VIN = VIN, min until Vo = 10% of Vo, set) Case 2: Input power is applied for at least one second and then the On/Off input is enabled (delay from instant at which Von/Off is enabled until Vo = 10% of Vo, set) Output voltage Rise time (time for Vo to rise from 10% of Vo, set to 90% of Vo, set) Output voltage overshoot (TA = 25oC VIN= VIN, min to VIN, max,IO = IO, min to IO, max) With or without maximum external capacitance Tref-Q1 123 133 143 C Tref-Q4 121 131 141 C All TWARN 120 130 140 C All VSEQ -Vo 100 mV All VSEQ -Vo 100 mV 2.7 2.95 Vdc Over Temperature Protection (See Thermal Considerations section) All PMBus Over Temperature Warning Threshold * Tracking Accuracy (Power-Up: 2V/ms) (Power-Down: 2V/ms) (VIN, min to VIN, max; IO, min to IO, max VSEQ < Vo) Input Undervoltage Lockout Turn-on Threshold All Turn-off Threshold All 2.4 2.75 Vdc Hysteresis All 0.05 0.4 Vdc PMBus Adjustable Input Under Voltage Lockout Thresholds All 2.5 Resolution of Adjustable Input Under Voltage Threshold All 14 Vdc 500 mV PGOOD (Power Good) Signal Interface Open Drain, Vsupply 5VDC Overvoltage threshold for PGOOD ON All 103 108 113 %VO, set Overvoltage threshold for PGOOD OFF All 100 105 110 %VO, set Undervoltage threshold for PGOOD ON All 105 110 115 %VO, set Undervoltage threshold for PGOOD OFF All 85 90 95 %VO, set Pulldown resistance of PGOOD pin All 50 Sink current capability into PGOOD pin All 5 mA * Over temperature Warning - Warning may not activate before alarm and unit may shutdown before warning September 7, 2017 (c)2017 General Electric Company. All rights reserved. Page 5 GE Data Sheet 20A Digital MicroDLynxTM: Non-Isolated DC-DC Power Modules 3Vdc -14.4Vdc input; 0.45Vdc to 5.5Vdc output; 20A Output Current Digital Interface Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. See Feature Descriptions for additional information. Parameter Conditions Symbol Min Input High Voltage (CLK, DATA) VIH 2.1 Input Low Voltage (CLK, DATA) VIL Input high level current (CLK, DATA) IIH Input low level current (CLK, DATA) IIL Typ Max Unit 3.6 V 0.8 V -10 10 A -10 10 A 0.4 V 10 A PMBus Signal Interface Characteristics Output Low Voltage (CLK, DATA, SMBALERT#) Output high level open drain leakage current (DATA, SMBALERT#) Pin capacitance PMBus Operating frequency range IOUT=2mA VOL VOUT=3.6V IOH 0 CO Slave Mode 0.7 pF FPMB 10 tHD:DAT 0 300 ns tSU:DAT 250 ns Read delay time tDLY 153 Output current measurement range IRNG 0 Output current measurement resolution IRES 62.5 Receive Mode Transmit Mode Data hold time Data setup time 400 kHz Measurement System Characteristics Output current measurement accuracy at 25C (with IOUT, CORR) Output current measurement offset VOUT measurement range 192 231 s 26 A mA IACC 5 % IOFST 0.1 A 5.5 V VOUT(rng) 0 15.62 5 VOUT measurement resolution VOUT(res) VOUT measurement accuracy VOUT, ACC -15 5 % VOUT measurement offset VOUT(ofst) -3 3 % VIN measurement range VIN(rng) 0 VIN measurement resolution VIN(res) VIN measurement accuracy VIN, ACC -15 VIN measurement offset VIN(ofst) -5.5 September 7, 2017 mV 14.4 32.5 (c)2017 General Electric Company. All rights reserved. -2 V mV 5 % 1.4 LSB Page 6 GE Data Sheet 20A Digital MicroDLynxTM: Non-Isolated DC-DC Power Modules 3Vdc -14.4Vdc input; 0.45Vdc to 5.5Vdc output; 20A Output Current Characteristic Curves The following figures provide typical characteristics for the 20A Digital MicroDLynxTM at 0.6Vo and 25oC. 22 90 85 18 OUTPUT CURRENT, Io (A) EFFICIENCY, (%) 80 Vin=3.3V 75 70 Vin=14V Vin=12V 65 60 55 50 0 5 10 15 NC 1m/s 10 (200LFM) 6 1.5m/s (300LFM) 55 65 105 OUTPUT OLTAGE VO (V) (10mV/div) IO (A) (10Adiv) INPUT VOLTAGE VIN (V) (5V/div) VO (V) (200mV/div) VON/OFF (V) (5V/div) VO (V) (200mV/div) 95 TIME, t (20s /div) OUTPUT VOLTAGE ON/OFF VOLTAGE OUTPUT VOLTAGE September 7, 2017 85 Figure 4. Transient Response to Dynamic Load Change from 50% to 100% at 12Vin, Cout= 1x47uF +11x330uF CTune=47nF, RTune=178 ohms TIME, t (2ms/div) Figure 5. Typical Start-up Using On/Off Voltage (Io = Io,max). 75 Figure 2. Derating Output Current versus Ambient Temperature and Airflow. TIME, t (1s/div) Figure 3. Typical output ripple and noise (CO=2x47F ceramic, VIN = 12V, Io = Io,max, ). 2m/s (400LFM) AMBIENT TEMPERATURE, TA OC OUTPUT CURRENT, VO (V) (10mV/div) OUTPUT VOLTAGE 14 2 20 OUTPUT CURRENT, IO (A) Figure 1. Converter Efficiency versus Output Current. 0.5m/s (100LFM) TIME, t (2ms/div) Figure 6. Typical Start-up Using Input Voltage (VIN = 12V, Io = Io,max). (c)2017 General Electric Company. All rights reserved. Page 7 GE Data Sheet 20A Digital MicroDLynxTM: Non-Isolated DC-DC Power Modules 3Vdc -14.4Vdc input; 0.45Vdc to 5.5Vdc output; 20A Output Current Characteristic Curves The following figures provide typical characteristics for the 20A Digital MicroDLynxTM at 1.2Vo and 25oC. 22 95 90 18 85 EFFICIENCY, (%) 80 OUTPUT CURRENT, Io (A) Vin=3.3V Vin=14V 75 Vin=12V 70 65 60 55 50 0 5 10 15 1.5m/s (300LFM) 6 1m/s (200LFM) 65 105 OUTPUT VOLTAGE VO (V) (20mV/div) IO (A) (10Adiv) INPUT VOLTAGE VIN (V) (5V/div) VO (V) (500mV/div) VON/OFF (V) (5V/div) 95 Figure 10. Transient Response to Dynamic Load Change from 50% to 100% at 12Vin, Cout= 1x47uF +5x330uF, CTune=10nF & RTune=178 ohms OUTPUT VOLTAGE ON/OFF VOLTAGE VO (V) (500mV/div) 85 TIME, t (20s /div) Figure 9. Typical output ripple and noise (CO=2x47F ceramic, VIN = 12V, Io = Io,max, ). OUTPUT VOLTAGE 75 Figure 8. Derating Output Current versus Ambient Temperature and Airflow. TIME, t (1s/div) TIME, t (2ms/div) Figure 11. Typical Start-up Using On/Off Voltage (Io = Io,max). September 7, 2017 2m/s (400LFM) AMBIENT TEMPERATURE, TA OC OUTPUT CURRENT, VO (V) (20mV/div) 0.5m/s (100LFM) 10 55 OUTPUT CURRENT, IO (A) OUTPUT VOLTAGE 14 2 20 Figure 7. Converter Efficiency versus Output Current. NC TIME, t (2ms/div) Figure 12. Typical Start-up Using Input Voltage (VIN = 12V, Io = Io,max). (c)2017 General Electric Company. All rights reserved. Page 8 GE Data Sheet 20A Digital MicroDLynxTM: Non-Isolated DC-DC Power Modules 3Vdc -14.4Vdc input; 0.45Vdc to 5.5Vdc output; 20A Output Current Characteristic Curves The following figures provide typical characteristics for the 20A Digital MicroDLynxTM at 1.8Vo and 25oC. 22 95 18 90 85 OUTPUT CURRENT, Io (A) EFFICIENCY, (%) Vin=3.3V Vin=14V Vin=12V 80 75 70 0.5m/s (100LFM) 10 5 10 15 20 1.5m/s (300LFM) 6 2m/s (400LFM) 55 OUTPUT CURRENT, IO (A) 65 OUTPUT VOLTAGE VO (V) (20mV/div) IO (A) (10Adiv) INPUT VOLTAGE VIN (V) (5V/div) VO (V) (500mV/div) VON/OFF (V) 5V/div) 105 TIME, t (20s /div) OUTPUT VOLTAGE ON/OFF VOLTAGE VO (V) (500mV/div) September 7, 2017 95 T A OC Figure 16. Transient Response to Dynamic Load Change from 50% to 100% at 12Vin, Cout= 2x47uF +3x330uF, CTune=5600pF & RTune=220 ohms TIME, t (2ms/div) Figure 17. Typical Start-up Using On/Off Voltage (Io = Io,max). 85 AMBIENT TEMPERATURE, TIME, t (1s/div) Figure 15. Typical output ripple and noise (CO=2X47F ceramic, VIN = 12V, Io = Io,max, ). 75 Figure 14. Derating Output Current versus Ambient Temperature and Airflow. OUTPUT CURRENT, VO (V) (20mV/div) Figure 13. Converter Efficiency versus Output Current. OUTPUT VOLTAGE 1m/s (200LFM) 2 0 OUTPUT VOLTAGE NC 14 TIME, t (2ms/div) Figure 18. Typical Start-up Using Input Voltage (VIN = 12V, Io = Io,max). (c)2017 General Electric Company. All rights reserved. Page 9 GE Data Sheet 20A Digital MicroDLynxTM: Non-Isolated DC-DC Power Modules 3Vdc -14.4Vdc input; 0.45Vdc to 5.5Vdc output; 20A Output Current Characteristic Curves The following figures provide typical characteristics for the 20A Digital MicroDLynxTM at 2.5Vo and 25oC. 22 100 Vin=12V 95 OUTPUT CURRENT, Io (A) 18 EFFICIENCY, (%) 90 Vin=4.5V 85 Vin=14V 80 75 70 NC 14 10 1.5m/s (300LFM) 6 2m/s (400LFM) 2 0 5 10 15 20 55 65 OUTPUT CURRENT, IO (A) 75 85 95 105 AMBIENT TEMPERATURE, TA OC OUTPUT VOLTAGE VO (V) (20mV/div) IO (A) (10Adiv) Figure 20. Derating Output Current versus Ambient Temperature and Airflow. OUTPUT CURRENT, VO (V) (20mV/div) Figure 19. Converter Efficiency versus Output Current. OUTPUT VOLTAGE 0.5m/s (100LFM) 1m/s (200LFM) TIME, t (1s/div) TIME, t (20s /div) INPUT VOLTAGE VIN (V) (5V/div) VO (V) (1V/div) VON/OFF (V) (5V/div) VO (V) (1V/div) OUTPUT VOLTAGE ON/OFF VOLTAGE OUTPUT VOLTAGE Figure 22. Transient Response to Dynamic Load Change from Figure 21. Typical output ripple and noise (CO=2x47F ceramic, 50% to 100% at 12Vin, Cout= 2x47uF +2x330uF, CTune=3300pF VIN = 12V, Io = Io,max, ). & RTune=220 ohms TIME, t (2ms/div) Figure 23. Typical Start-up Using On/Off Voltage (Io = Io,max). September 7, 2017 TIME, t (2ms/div) Figure 24. Typical Start-up Using Input Voltage (VIN = 12V, Io = Io,max). (c)2017 General Electric Company. All rights reserved. Page 10 GE Data Sheet 20A Digital MicroDLynxTM: Non-Isolated DC-DC Power Modules 3Vdc -14.4Vdc input; 0.45Vdc to 5.5Vdc output; 20A Output Current Characteristic Curves The following figures provide typical characteristics for the 20A Digital MicroDLynxTM at 3.3Vo and 25oC. 22 100 Vin=12V 95 OUTPUT CURRENT, Io (A) 18 EFFICIENCY, (%) 90 Vin=14V 85 Vin=4.5V 80 75 70 0.5m/s (100LFM) 1m/s (200LFM) 1.5m/s (300LFM) 14 10 6 2m/s (400LFM) 2 0 5 10 15 20 55 OUTPUT CURRENT, IO (A) 65 OUTPUT VOLTAGE VO (V) (50mV/div) IO (A) (10Adiv) INPUT VOLTAGE VIN (V) (5V/div) VO (V) (1V/div) VO (V) (1V/div) 105 Figure 28 Transient Response to Dynamic Load Change from 50% to 100% at 12Vin, Cout= 5x47uF +1x330uF, CTune=2200pF & RTune=220 ohms OUTPUT VOLTAGE ON/OFF VOLTAGE VON/OFF (V) (5V/div) OUTPUT VOLTAGE September 7, 2017 95 TIME, t (20s /div) TIME, t (2ms/div) Figure 29. Typical Start-up Using On/Off Voltage (Io = Io,max). 85 Figure 26. Derating Output Current versus Ambient Temperature and Airflow. TIME, t (1s/div) Figure 27. Typical output ripple and noise (CO=2x47F ceramic, VIN = 12V, Io = Io,max, ). 75 AMBIENT TEMPERATURE, TA OC OUTPUT CURRENT, VO (V) (50mV/div) Figure 25. Converter Efficiency versus Output Current. OUTPUT VOLTAGE NC TIME, t (2ms/div) Figure 30. Typical Start-up Using Input Voltage (VIN = 12V, Io = Io,max). (c)2017 General Electric Company. All rights reserved. Page 11 GE Data Sheet 20A Digital MicroDLynxTM: Non-Isolated DC-DC Power Modules 3Vdc -14.4Vdc input; 0.45Vdc to 5.5Vdc output; 20A Output Current Characteristic Curves The following figures provide typical characteristics for the 20A Digital MicroDLynxTM at 5Vo and 25oC. 100 22 Vin=12V 95 OUTPUT CURRENT, Io (A) 18 EFFICIENCY, (%) 90 Vin=7V Vin=14V 85 80 75 70 0.5m/s (100LFM) 1m/s (200LFM) 1.5m/s (300LFM) 14 10 2m/s (400LFM) 6 2 0 5 10 15 20 55 OUTPUT CURRENT, IO (A) 65 OUTPUT VOLTAGE VO (V) (50mV/div) IO (A) (10Adiv) INPUT VOLTAGE VIN (V) (5V/div) VO (V) (2V/div) VO (V) (2V/div) 105 Figure 34. Transient Response to Dynamic Load Change from 50% to 100% at 12Vin, Cout= 8x47uF, CTune=1500pF & RTune=220 ohms OUTPUT VOLTAGE ON/OFF VOLTAGE VON/OFF (V) (5V/div) OUTPUT VOLTAGE September 7, 2017 95 TIME, t (20s /div) TIME, t (2ms/div) Figure 35. Typical Start-up Using On/Off Voltage (Io = Io,max). 85 Figure 32. Derating Output Current versus Ambient Temperature and Airflow. TIME, t (1s/div) Figure 33. Typical output ripple and noise (CO=2x47F ceramic, VIN = 12V, Io = Io,max, ). 75 AMBIENT TEMPERATURE, TA OC OUTPUT CURRENT, VO (V) (50mV/div) Figure 31. Converter Efficiency versus Output Current. OUTPUT VOLTAGE NC TIME, t (2ms/div) Figure 36. Typical Start-up Using Input Voltage (VIN = 12V, Io = Io,max). (c)2017 General Electric Company. All rights reserved. Page 12 GE Data Sheet 20A Digital MicroDLynxTM: Non-Isolated DC-DC Power Modules 3Vdc -14.4Vdc input; 0.45Vdc to 5.5Vdc output; 20A Output Current 70 Input Filtering 60 The 20A Digital MicroDLynxTM module should be connected to a low ac-impedance source. A highly inductive source can affect the stability of the module. An input capacitance must be placed directly adjacent to the input pin of the module, to minimize input ripple voltage and ensure module stability. 50 To minimize input voltage ripple, ceramic capacitors are recommended at the input of the module. Figure 37 shows the input ripple voltage for various output voltages at 20A of load current with 2x22 F or 3x22 F ceramic capacitors and an input of 12V. Ripple (mVp-p) Design Considerations 2x47uF Ext Cap 4x47uF Ext Cap 6x47uF Ext Cap 8x47uF Ext Cap 40 30 20 10 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 Output Voltage(Volts) Input Ripple Voltage (mVp-p) 450 400 Figure 38. Output ripple voltage for various output voltages with external 2x47 F, 4x47 F or 6x47 F ceramic capacitors at the output (20A load). Input voltage is 12V. 2x22uF 350 3x22 uF 300 250 200 Safety Considerations 150 100 50 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 Output Voltage (Vdc) Figure 37. Input ripple voltage for various output voltages with 2x22 F or 3x22 F ceramic capacitors at the input (20A load). Input voltage is 12V. Output Filtering These modules are designed for low output ripple voltage and will meet the maximum output ripple specification with 0.1 F ceramic and 2x47 F ceramic capacitors at the output of the module. However, additional output filtering may be required by the system designer for a number of reasons. First, there may be a need to further reduce the output ripple and noise of the module. Second, the dynamic response characteristics may need to be customized to a particular load step change. For safety agency approval the power module must be installed in compliance with the spacing and separation requirements of the end-use safety agency standards, i.e., UL 60950-1 2nd, CSA C22.2 No. 60950-1-07, DIN EN 609501:2006 + A11 (VDE0805 Teil 1 + A11):2009-11; EN 609501:2006 + A11:2009-03. For the converter output to be considered meeting the requirements of safety extra-low voltage (SELV), the input must meet SELV requirements. The power module has extra-low voltage (ELV) outputs when all inputs are ELV. The UDT020A0X series were tested using an external Littelfuse 456 series fast-acting fuse rated at 30 A, 100 Vdc in the ungrounded input. To reduce the output ripple and improve the dynamic response to a step load change, additional capacitance at the output can be used. Low ESR polymer and ceramic capacitors are recommended to improve the dynamic response of the module. Figure 38 provides output ripple information for different external capacitance values at various Vo and a full load current of 20A. For stable operation of the module, limit the capacitance to less than the maximum output capacitance as specified in the electrical specification table. Optimal performance of the module can be achieved by using the Tunable LoopTM feature described later in this data sheet. September 7, 2017 (c)2017 General Electric Company. All rights reserved. Page 13 GE Data Sheet 20A Digital MicroDLynxTM: Non-Isolated DC-DC Power Modules 3Vdc -14.4Vdc input; 0.45Vdc to 5.5Vdc output; 20A Output Current Analog Feature Descriptions Digital On/Off Remote On/Off Please see the Digital Feature Descriptions section. The module can be turned ON and OFF either by using the ON/OFF pin (Analog interface) or through the PMBus interface (Digital). The module can be configured in a number of ways through the PMBus interface to react to the two ON/OFF inputs: * * * Module ON/OFF can be controlled only through the analog interface (digital interface ON/OFF commands are ignored) Module ON/OFF can be controlled only through the PMBus interface (analog interface is ignored) Module ON/OFF can be controlled by either the analog or digital interface The default state of the module (as shipped from the factory) is to be controlled by the analog interface only. If the digital interface is to be enabled, or the module is to be controlled only through the digital interface, this change must be made through the PMBus. These changes can be made and written to non-volatile memory on the module so that it is remembered for subsequent use. Analog On/Off For positive logic modules, the circuit configuration for using the On/Off pin is shown in Figure 39. When the external transistor Q2 is in the OFF state, the internal transistor Q7 is turned ON, which turn Q3 OFF which keeps Q6 OFF and Q5 OFF. This allows the internal PWM #Enable signal to be pulled up by the internal 3.3V, thus turning the module ON. When transistor Q2 is turned ON, the On/Off pin is pulled low, which turns Q7 OFF which turns Q3, Q6 and Q5 ON and the internal PWM #Enable signal is pulled low and the module is OFF. A suggested value for Rpullup is 20k. For negative logic On/Off modules, the circuit configuration is shown in Fig. 40. The On/Off pin should be pulled high with an external pull-up resistor (suggested value for the 3V to 14V input range is 20Kohms). When transistor Q2 is in the OFF state, the On/Off pin is pulled high, transistor Q3 is turned ON. This turns Q6 ON, followed by Q5 turning ON which pulls the internal ENABLE low and the module is OFF. To turn the module ON, Q2 is turned ON pulling the On/Off pin low, turning transistor Q3 OFF, which keeps Q6 and Q5 OFF resulting in the PWM Enable pin going high. September 7, 2017 ENABLE VIN 47K 470 20K Rpullup 100pF 20K Q6 4.7K I ON/OFF Q3 20K 100K 20K 2K 20K Q2 Q5 20K Q7 + 20K 20K V ON/OFF _ GND Figure 39. Circuit configuration for using positive On/Off logic. DLYNX MODULE 3.3V +VIN ENABLE Rpullup ON/OFF 47K 470 100pF I 20K Q6 4.7K Q3 + Q5 100K Q2 20K 2K V ON/OFF The 20A Digital MicroDLynxTM power modules feature an On/Off pin for remote On/Off operation. Two On/Off logic options are available. In the Positive Logic On/Off option, (device code suffix "4" - see Ordering Information), the module turns ON during a logic High on the On/Off pin and turns OFF during a logic Low. With the Negative Logic On/Off option, (no device code suffix, see Ordering Information), the module turns OFF during logic High and ON during logic Low. The On/Off signal should be always referenced to ground. For either On/Off logic option, leaving the On/Off pin disconnected will turn the module ON when input voltage is present. 3.3V DLYNX MODULE +VIN _ 20K 20K GND Figure 40. Circuit configuration for using negative On/Off logic. Monotonic Start-up and Shutdown The module has monotonic start-up and shutdown behavior for any combination of rated input voltage, output current and operating temperature range. Startup into Pre-biased Output The module can start into a prebiased output as long as the prebias voltage is 0.5V less than the set output voltage. Analog Output Voltage Programming The output voltage of the module is programmable to any voltage from 0.6dc to 5.5Vdc by connecting a resistor between the Trim and SIG_GND pins of the module. Certain restrictions apply on the output voltage set point depending on the input voltage. These are shown in the Output Voltage vs. Input Voltage Set Point Area plot in Fig. 41. The Upper Limit curve shows that for output voltages lower than 1V, the input voltage must be lower than the maximum of 14.4V. The Lower Limit curve shows that for output voltages higher than 0.6V, the input voltage needs to be larger than (c)2017 General Electric Company. All rights reserved. Page 14 GE Data Sheet 20A Digital MicroDLynxTM: Non-Isolated DC-DC Power Modules 3Vdc -14.4Vdc input; 0.45Vdc to 5.5Vdc output; 20A Output Current Table 1 the minimum of 3V. . 16 VO, set (V) 0.6 0.9 1.0 1.2 1.5 1.8 2.5 3.3 5.0 Input Voltage (v) 14 12 Upper 10 8 6 4 Lower 2 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 Rtrim (K) Open 40 30 20 13.33 10 6.316 4.444 2.727 6 Output Voltage (V) Figure 41. Output Voltage vs. Input Voltage Set Point Area plot showing limits where the output voltage can be set for different input voltages. VIN(+) Digital Output Voltage Adjustment Please see the Digital Feature Descriptions section. Remote Sense The power module has a Remote Sense feature to minimize the effects of distribution losses by regulating the voltage between the sense pins (VS+ and VS-). The voltage drop between the sense pins and the VOUT and GND pins of the module should not exceed 0.5V. VO(+) VS+ Analog Voltage Margining ON/OFF LOAD TRIM Rtrim SIG_GND VS Caution - Do not connect SIG_GND to GND elsewhere in the layout Figure 42. Circuit configuration for programming output voltage using an external resistor. Output voltage margining can be implemented in the module by connecting a resistor, Rmargin-up, from the Trim pin to the ground pin for margining-up the output voltage and by connecting a resistor, Rmargin-down, from the Trim pin to output pin for margining-down. Figure 43 shows the circuit configuration for output voltage margining. The POL Programming Tool, available at www.gecriticalpower.com under the Downloads section, also calculates the values of Rmargin-up and Rmargin-down for a specific output voltage and % margin. Please consult your local GE technical representative for additional details. Vo Rmargin-down Without an external resistor between Trim and SIG_GND pins, the output of the module will be 0.6Vdc. To calculate the value of the trim resistor, Rtrim for a desired output voltage, should be as per the following equation: MODULE Q2 Trim 12 Rtrim k Vo 0.6 Rmargin-up Rtrim Rtrim is the external resistor in k Q1 Vo is the desired output voltage. SIG_GND Table 1 provides Rtrim values required for some common output voltages. September 7, 2017 Figure 43. Circuit Configuration for margining Output voltage. (c)2017 General Electric Company. All rights reserved. Page 15 GE Data Sheet 20A Digital MicroDLynxTM: Non-Isolated DC-DC Power Modules 3Vdc -14.4Vdc input; 0.45Vdc to 5.5Vdc output; 20A Output Current Please see the Digital Feature Descriptions section. continue operation without interruption as the response to this fault (see the description of the PMBus command VOUT_UV_FAULT_RESPONSE for additional information). Output Voltage Sequencing Overcurrent Protection The power module includes a sequencing feature, EZSEQUENCE that enables users to implement various types of output voltage sequencing in their applications. This is accomplished via an additional sequencing pin. When not using the sequencing feature, leave it unconnected. To provide protection in a fault (output overload) condition, the unit is equipped with internal current-limiting circuitry and can endure current limiting continuously. At the point of current-limit inception, the unit enters hiccup mode. The unit operates normally once the output current is brought back into its specified range. Digital Output Voltage Margining The voltage applied to the SEQ pin should be scaled down by the same ratio as used to scale the output voltage down to the reference voltage of the module. This is accomplished by an external resistive divider connected across the sequencing voltage before it is fed to the SEQ pin as shown in Fig. 44. In addition, a small capacitor (suggested value 100pF) should be connected across the lower resistor R1. For all DLynx modules, the minimum recommended delay between the ON/OFF signal and the sequencing signal is 10ms to ensure that the module output is ramped up according to the sequencing signal. This ensures that the module soft-start routine is completed before the sequencing signal is allowed to ramp up. DLynx Module Digital Adjustable Overcurrent Warning Please see the Digital Feature Descriptions section. Overtemperature Protection To provide protection in a fault condition, the unit is equipped with a thermal shutdown circuit. The unit will shut down if the over-temperature threshold of 128oC ~ 130 oC (typ) is exceeded at the thermal reference point Tref .Please refer to Electrical characteristic table, over-temperature section on page 5. Once the unit goes into thermal shutdown it will then wait to cool before attempting to restart. Digital Temperature Status via PMBus Please see the Digital Feature Descriptions section. V SEQ Digitally Adjustable Output Over and Under Voltage Protection 20K Please see the Digital Feature Descriptions section. SEQ Input Undervoltage Lockout R1=Rtrim 100 pF SIG_GND Figure 44. Circuit showing connection of the sequencing signal to the SEQ pin. When the scaled down sequencing voltage is applied to the SEQ pin, the output voltage tracks this voltage until the output reaches the set-point voltage. The final value of the sequencing voltage must be set higher than the set-point voltage of the module. The output voltage follows the sequencing voltage on a one-to-one basis. By connecting multiple modules together, multiple modules can track their output voltages to the voltage applied on the SEQ pin. To initiate simultaneous shutdown of the modules, the SEQ pin voltage is lowered in a controlled manner. The output voltage of the modules tracks the voltages below their setpoint voltages on a one-to-one basis. A valid input voltage must be maintained until the tracking and output voltages reach ground potential. At input voltages below the input undervoltage lockout limit, the module operation is disabled. The module will begin to operate at an input voltage above the undervoltage lockout turn-on threshold. Digitally Adjustable Input Undervoltage Lockout Please see the Digital Feature Descriptions section. Digitally Adjustable Power Good Thresholds Please see the Digital Feature Descriptions section. Note that in all digital DLynx series of modules, the PMBus Output Undervoltage Fault will be tripped when sequencing is employed. This will be detected using the STATUS_WORD and STATUS_VOUT PMBus commands. In addition, the SMBALERT# signal will be asserted low as occurs for all faults and warnings. To avoid the module shutting down due to the Output Undervoltage Fault, the module must be set to September 7, 2017 (c)2017 General Electric Company. All rights reserved. Page 16 GE Data Sheet 20A Digital MicroDLynxTM: Non-Isolated DC-DC Power Modules 3Vdc -14.4Vdc input; 0.45Vdc to 5.5Vdc output; 20A Output Current Synchronization The module switching frequency can be synchronized to a signal with an external frequency within a specified range. Synchronization can be done by using the external signal applied to the SYNC pin of the module as shown in Fig. 45, with the converter being synchronized by the rising edge of the external signal. The Electrical Specifications table specifies the requirements of the external SYNC signal. If the SYNC pin is not used, the module should free run at the default switching frequency. If synchronization is not being used, connect the SYNC pin to GND. Larger values of external capacitance could also cause the module to become unstable. The Tunable LoopTM allows the user to externally adjust the voltage control loop to match the filter network connected to the output of the module. The Tunable LoopTM is implemented by connecting a series R-C between the VS+ and TRIM pins of the module, as shown in Fig. 46. This R-C allows the user to externally adjust the voltage loop feedback compensation of the module. VOUT VS+ MODULE RTune MODULE SYNC + CO CTune TRIM GND RTrim Figure 45. External source connections to synchronize switching frequency of the module. Measuring Output Current, Output Voltage and Input Voltage Please see the Digital Feature Descriptions section. Dual Layout Identical dimensions and pin layout of Analog and Digital MicroDLynx modules permit migration from one to the other without needing to change the layout. In both cases the trim resistor is connected between trim and signal ground. The output of the analog module cannot be trimmed down to 0.45V Power Good The module provides a Power Good (PGOOD) signal that is implemented with an open-drain output to indicate that the output voltage is within the regulation limits of the power module. The PGOOD signal will be de-asserted to a low state if any condition such as overtemperature, overcurrent or loss of regulation occurs that would result in the output voltage going 10% outside the setpoint value. The PGOOD terminal can be connected through a pullup resistor (suggested value 100K) to a source of 5VDC or lower. Tunable LoopTM SIG_GND GND Figure. 46. Circuit diagram showing connection of RTUME and CTUNE to tune the control loop of the module. Recommended values of RTUNE and CTUNE for different output capacitor combinations are given in Tables 2 and 3. Table 3 shows the recommended values of RTUNE and CTUNE for different values of ceramic output capacitors up to 1000uF that might be needed for an application to meet output ripple and noise requirements. Selecting RTUNE and CTUNE according to Table 3 will ensure stable operation of the module. In applications with tight output voltage limits in the presence of dynamic current loading, additional output capacitance will be required. Table 3 lists recommended values of RTUNE and CTUNE in order to meet 2% output voltage deviation limits for some common output voltages in the presence of a 10A to 20A step change (50% of full load), with an input voltage of 12V. Please contact your GE technical representative to obtain more details of this feature as well as for guidelines on how to select the right value of external R-C to tune the module for best transient performance and stable operation for other output capacitance values. The module has a feature that optimizes transient response of the module called Tunable LoopTM. External capacitors are usually added to the output of the module for two reasons: to reduce output ripple and noise (see Figure 38) and to reduce output voltage deviations from the steady-state value in the presence of dynamic load current changes. Adding external capacitance however affects the voltage control loop of the module, typically causing the loop to slow down with sluggish response. September 7, 2017 (c)2017 General Electric Company. All rights reserved. Page 17 GE Data Sheet 20A Digital MicroDLynxTM: Non-Isolated DC-DC Power Modules 3Vdc -14.4Vdc input; 0.45Vdc to 5.5Vdc output; 20A Output Current Table 2. General recommended values of of RTUNE and CTUNE for Vin=12V and various external ceramic capacitor combinations. Co 2x47F 4x47F 6x47F 10x47F RTUNE 330 330 270 220 180 CTUNE 47pF 560pF 1200pF 2200pF 4700pF 20x47F Table 3. Recommended values of RTUNE and CTUNE to obtain transient deviation of 2% of Vout for a 10A step load with Vin=12V. Vo Co 5V 3.3V 2.5V 1.8V 2x47F 2x47F 5x47F + + + 8x47F 1x330F 2x330F 3x330F Polymer Polymer Polymer RTUNE 220 220 220 220 CTUNE 1500pF 2200pF 3300pF 5600pF V 100mV 64mV 49mV 36mV 1.2V 0.6V 1x47F 1x47F + + 5x330F 11x330F Polymer Polymer 180 180 10nF 47nF 24mV 12mV Note: The capacitors used in the Tunable Loop tables are 47 F/3 m ESR ceramic and 330 F/12 m ESR polymer capacitors. September 7, 2017 (c)2017 General Electric Company. All rights reserved. Page 18 GE Data Sheet 20A Digital MicroDLynxTM: Non-Isolated DC-DC Power Modules 3Vdc -14.4Vdc input; 0.45Vdc to 5.5Vdc output; 20A Output Current Digital Feature Descriptions either address resistor value is outside the range specified in Table 4, the module will respond to address 127. PMBus Interface Capability Table 4 The 20A Digital MicroDLynxTM power modules have a PMBus interface that supports both communication and control. The PMBus Power Management Protocol Specification can be obtained from www.pmbus.org. The modules support a subset of version 1.1 of the specification (see Table 6 for a list of the specific commands supported). Most module parameters can be programmed using PMBus and stored as defaults for later use. All communication over the module PMBus interface must support the Packet Error Checking (PEC) scheme. The PMBus master must generate the correct PEC byte for all transactions, and check the PEC byte returned by the module. The module also supports the SMBALERT# response protocol whereby the module can alert the bus master if it wants to talk. For more information on the SMBus alert response protocol, see the System Management Bus (SMBus) specification. The module has non-volatile memory that is used to store configuration settings. Not all settings programmed into the device are automatically saved into this non-volatile memory, only those specifically identified as capable of being stored can be saved (see Table 6 for which command parameters can be saved to non-volatile storage). Digit 0 1 2 3 4 5 6 7 The user must know which I2C addresses are reserved in a system for special functions and set the address of the module to avoid interfering with other system operations. Both 100kHz and 400kHz bus speeds are supported by the module. Connection for the PMBus interface should follow the High Power DC specifications given in section 3.1.3 in the SMBus specification V2.0 for the 400kHz bus speed or the Low Power DC specifications in section 3.1.2. The complete SMBus specification is available from the SMBus web site, smbus.org. ADDR1 PMBus Data Format ADDR0 For commands that set thresholds, voltages or report such quantities, the module supports the "Linear" data format among the three data formats supported by PMBus. The Linear Data Format is a two byte value with an 11-bit, two's complement mantissa and a 5-bit, two's complement exponent. The format of the two data bytes is shown below: Data Byte High 7 6 5 4 3 Data Byte Low 2 1 0 7 6 5 4 3 2 1 0 Exponent MSB Mantissa MSB The value is of the number is then given by Value = Mantissa x 2 Exponent PMBus Addressing The power module can be addressed through the PMBus using a device address. The module has 64 possible addresses (0 to 63 in decimal) which can be set using resistors connected from the ADDR0 and ADDR1 pins to GND. Note that some of these addresses (0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11 12, 40, 44, 45, 55 in decimal) are reserved according to the SMBus specifications and may not be useable. The address is set in the form of two octal (0 to 7) digits, with each pin setting one digit. The ADDR1 pin sets the high order digit and ADDR0 sets the low order digit. The resistor values suggested for each digit are shown in Table 4 (1% tolerance resistors are recommended). Note that if September 7, 2017 Resistor Value (K) 10 15.4 23.7 36.5 54.9 84.5 130 200 RADDR0 RADDR1 SIG_GND Figure 47. Circuit showing connection of resistors used to set the PMBus address of the module. PMBus Enabled On/Off The module can also be turned on and off via the PMBus interface. The OPERATION command is used to actually turn the module on and off via the PMBus, while the ON_OFF_CONFIG command configures the combination of analog ON/OFF pin input and PMBus commands needed to turn the module on and off. Bit [7] in the OPERATION command data byte enables the module, with the following functions: 0 1 : : Output is disabled Output is enabled This module uses the lower five bits of the ON_OFF_CONFIG data byte to set various ON/OFF options as follows: Bit Position Access Function Default Value (c)2017 General Electric Company. All rights reserved. 4 r/w PU 1 3 r/w CMD 0 2 r/w CPR 1 1 r/w POL 1 0 r CPA 1 Page 19 GE Data Sheet 20A Digital MicroDLynxTM: Non-Isolated DC-DC Power Modules 3Vdc -14.4Vdc input; 0.45Vdc to 5.5Vdc output; 20A Output Current PU: Sets the default to either operate any time input power is present or for the ON/OFF to be controlled by the analog ON/OFF input and the PMBus OPERATION command. This bit is used together with the CP, CMD and ON bits to determine startup. Bit Value 0 1 Action Module powers up any time power is present regardless of state of the analog ON/OFF pin Module does not power up until commanded by the analog ON/OFF pin and the OPERATION command as programmed in bits [2:0] of the ON_OFF_CONFIG register. CMD: The CMD bit controls how the device responds to the OPERATION command. Bit Value 0 1 Action Module ignores the ON bit in the OPERATION command Module responds to the ON bit in the OPERATION command CPR: Sets the response of the analog ON/OFF pin. This bit is used together with the CMD, PU and ON bits to determine startup. Bit Value 0 1 Action Module ignores the analog ON/OFF pin, i.e. ON/OFF is only controlled through the PMBUS via the OPERATION command Module requires the analog ON/OFF pin to be asserted to start the unit PMBus Adjustable Soft Start Rise Time The soft start rise time can be adjusted in the module via PMBus. When setting this parameter, make sure that the charging current for output capacitors can be delivered by the module in addition to any load current to avoid nuisance tripping of the overcurrent protection circuitry during startup. The TON_RISE command sets the rise time in ms, and allows choosing soft start times between 600s and 9ms, with possible values listed in Table 5. Note that the exponent is fixed at -4 (decimal) and the upper two bits of the mantissa are also fixed at 0. Table 5 Rise Time 600s 900s 1.2ms 1.8ms 2.7ms 4.2ms 6.0ms 9.0ms September 7, 2017 Exponent 11100 11100 11100 11100 11100 11100 11100 11100 Mantissa 00000001010 00000001110 00000010011 00000011101 00000101011 00001000011 00001100000 00010010000 Output Voltage Adjustment Using the PMBus The VOUT_SCALE_LOOP parameter is important for a number of PMBus commands related to output voltage trimming, margining, over/under voltage protection and the PGOOD thresholds. The output voltage of the module is set as the combination of the voltage divider formed by RTrim and a 20k upper divider resistor inside the module, and the internal reference voltage of the module. The reference voltage VREF is nominally set at 600mV, and the output regulation voltage is then given by 20000 RTrim VOUT VREF RTrim Hence the module output voltage is dependent on the value of RTrim which is connected external to the module. The information on the output voltage divider ratio is conveyed to the module through the VOUT_SCALE_LOOP parameter which is calculated as follows: VOUT _ SCALE _ LOOP RTrim 20000 RTrim The VOUT_SCALE_LOOP parameter is specified using the "Linear" format and two bytes. The upper five bits [7:3] of the high byte are used to set the exponent which is fixed at -9 (decimal). The remaining three bits of the high byte [2:0] and the eight bits of the lower byte are used for the mantissa. The default value of the mantissa is 00100000000 corresponding to 256 (decimal), corresponding to a divider ratio of 0.5. The maximum value of the mantissa is 512 corresponding to a divider ratio of 1. Note that the resolution of the VOUT_SCALE_LOOP command is 0.2%. When PMBus commands are used to trim or margin the output voltage, the value of VREF is what is changed inside the module, which in turn changes the regulated output voltage of the module. The nominal output voltage of the module can be adjusted with a minimum step size of 0.4% over a 25% range from nominal using the VOUT_TRIM command over the PMBus. The VOUT_TRIM command is used to apply a fixed offset voltage to the output voltage command value using the "Linear" mode with the exponent fixed at -10 (decimal). The value of the offset voltage is given by VOUT (offset) VOUT _ TRIM 2 10 This offset voltage is added to the voltage set through the divider ratio and nominal VREF to produce the trimmed output voltage. The valid range in two's complement for this command is -4000h to 3fffh. The high order two bits of the high byte must both be either 0 or 1. If a value outside of the +/-25% adjustment range is given with this command, the module will set it's output voltage to the nominal value (as if VOUT_TRIM had been set to 0), assert SMBALRT#, set the CML bit in STATUS_BYTE and the invalid data bit in STATUS_CML. (c)2017 General Electric Company. All rights reserved. Page 20 GE Data Sheet 20A Digital MicroDLynxTM: Non-Isolated DC-DC Power Modules 3Vdc -14.4Vdc input; 0.45Vdc to 5.5Vdc output; 20A Output Current Output Voltage Margining Using the PMBus The module can also have its output voltage margined via PMBus commands. The command VOUT_MARGIN_HIGH sets the margin high voltage, while the command VOUT_MARGIN_LOW sets the margin low voltage. Both the VOUT_MARGIN_HIGH and VOUT_MARGIN_LOW commands use the "Linear" mode with the exponent fixed at -10 (decimal). Two bytes are used for the mantissa with the upper bit [7] of the high byte fixed at 0. The actual margined output voltage is a combination of the VOUT_MARGIN_HIGH or VOUT_MARGIN_LOW and the VOUT_TRIM values as shown below. VOUT ( MH ) (VOUT _ MARGIN _ HIGH VOUT _ TRIM ) 2 10 VOUT ( ML) (VOUT _ MARGIN _ LOW VOUT _ TRIM ) 2 10 Note that the sum of the margin and trim voltages cannot be outside the 25% window around the nominal output voltage. The data associated with VOUT_MARGIN_HIGH and VOUT_MARGIN_LOW can be stored to non-volatile memory using the STORE_DEFAULT_ALL command. The module is commanded to go to the margined high or low voltages using the OPERATION command. Bits [5:2] are used to enable margining as follows: 00XX 0101 0110 1001 1010 : : : : : Margin Off Margin Low (Ignore Fault) Margin Low (Act on Fault) Margin High (Ignore Fault) Margin High (Act on Fault) PMBus Adjustable Overcurrent Warning The module can provide an overcurrent warning via the PMBus. The threshold for the overcurrent warning can be set using the parameter IOUT_OC_WARN_LIMIT. This command uses the "Linear" data format with a two byte data word where the upper five bits [7:3] of the high byte represent the exponent and the remaining three bits of the high byte [2:0] and the eight bits in the low byte represent the mantissa. The exponent is fixed at -1 (decimal). The upper five bits of the mantissa are fixed at 0 while the lower six bits are programmable. For production codes after April 2013, the value for IOUT_OC_WARN_LIMIT will be fixed at 25A. For earlier production codes the actual value for IOUT_OC_WARN_LIMIT will vary from module to module due to calibration during production testing. The resolution of this warning limit is 500mA. The value of the IOUT_OC_WARN_LIMIT can be stored to non-volatile memory using the STORE_DEFAULT_ALL command. PMBus Adjustable Output Over and Under Voltage Protection The module has output over and under voltage protection capability. The PMBus command VOUT_OV_FAULT_LIMIT is used to set the output over voltage threshold from four possible values: 108%, 110%, 112% or 115% of the commanded output voltage. The command VOUT_UV_FAULT_LIMIT sets the threshold that causes an output under voltage fault and can also be selected from four possible values: 92%, 90%, 88% or 85%. The default values are 112% and 88% of commanded output voltage. Both commands use two data bytes formatted as two's complement binary integers. The "Linear" mode is used with the exponent fixed to -10 (decimal) and the effective over or under voltage trip points given by: VOUT (OV _ REQ ) (VOUT _ OV _ FAULT _ LIMIT ) 2 10 VOUT (UV _ REQ ) (VOUT _ UV _ FAULT _ LIMIT ) 2 10 Values within the supported range for over and undervoltage detection thresholds will be set to the nearest fixed percentage. Note that the correct value for VOUT_SCALE_LOOP must be set in the module for the correct over or under voltage trip points to be calculated. In addition to adjustable output voltage protection, the 12A Digital Pico DLynxTM module can also be programmed for the response to the fault. The VOUT_OV_FAULT RESPONSE and VOUT_UV_FAULT_RESPONSE commands specify the response to the fault. Both these commands use a single data byte with the possible options as shown below. 1. Continue operation without interruption (Bits [7:6] = 00, Bits [5:3] = xxx) 2. Continue for four switching cycles and then shut down if the fault is still present, followed by no restart or continuous restart (Bits [7:6] = 01, Bits [5:3] = 000 means no restart, Bits [5:3] = 111 means continuous restart) 3. Immediate shut down followed by no restart or continuous restart (Bits [7:6] = 10, Bits [5:3] = 000 means no restart, Bits [5:3] = 111 means continuous restart). 4. Module output is disabled when the fault is present and the output is enabled when the fault no longer exists (Bits [7:6] = 11, Bits [5:3] = xxx). Note that separate response choices are possible for output over voltage or under voltage faults. Temperature Status via PMBus The module can provide information related to temperature of the module through the STATUS_TEMPERATURE command. The command returns information about whether the pre-set over temperature fault threshold and/or the warning threshold have been exceeded. September 7, 2017 (c)2017 General Electric Company. All rights reserved. Page 21 GE Data Sheet 20A Digital MicroDLynxTM: Non-Isolated DC-DC Power Modules 3Vdc -14.4Vdc input; 0.45Vdc to 5.5Vdc output; 20A Output Current PMBus Adjustable Input Undervoltage Lockout The module allows adjustment of the input under voltage lockout and hysteresis. The command VIN_ON allows setting the input voltage turn on threshold, while the VIN_OFF command sets the input voltage turn off threshold. For the VIN_ON command, possible values are 2.75V, and 3V to 14V in 0.5V steps. For the VIN_OFF command, possible values are 2.5V to 14V in 0.5V steps. If other values are entered for either command, they will be mapped to the closest of the allowed values. Both the VIN_ON and VIN_OFF commands use the "Linear" format with two data bytes. The upper five bits represent the exponent (fixed at -2) and the remaining 11 bits represent the mantissa. For the mantissa, the four most significant bits are fixed at 0. Power Good The module provides a Power Good (PGOOD) signal that is implemented with an open-drain output to indicate that the output voltage is within the regulation limits of the power module. The PGOOD signal will be de-asserted to a low state if any condition such as overtemperature, overcurrent or loss of regulation occurs that would result in the output voltage going outside the specified thresholds. The PGOOD thresholds are user selectable via the PMBus (the default values are as shown in the Feature Specifications Section). Each threshold is set up symmetrically above and below the nominal value. The POWER_GOOD_ON command sets the output voltage level above which PGOOD is asserted (lower threshold). For example, with a 1.2V nominal output voltage, the POWER_GOOD_ON threshold can set the lower threshold to 1.14 or 1.1V. Doing this will automatically set the upper thresholds to 1.26 or 1.3V. The POWER_GOOD_OFF command sets the level below which the PGOOD command is de-asserted. This command also sets two thresholds symmetrically placed around the nominal output voltage. Normally, the POWER_GOOD_ON threshold is set higher than the POWER_GOOD_OFF threshold. Both POWER_GOOD_ON and POWER_GOOD_OFF commands use the "Linear" format with the exponent fixed at -10 (decimal). The two thresholds are given by VOUT ( PGOOD _ ON ) ( POWER _ GOOD _ ON ) 2 10 VOUT ( PGOOD _ OFF ) ( POWER _ GOOD _ OFF ) 2 10 Both commands use two data bytes with bit [7] of the high byte fixed at 0, while the remaining bits are r/w and used to set the mantissa using two's complement representation. Both commands also use the The VOUT_SCALE_LOOP parameter so it must be set correctly. The default value of POWER_GOOD_ON is set at 1.1035V and that of the POWER_GOOD_OFF is set at 1.08V. The values associated with these commands can be stored in non-volatile memory using the STORE_DEFAULT_ALL command. September 7, 2017 PGOOD terminal can be connected through a pullup resistor (suggested value 100K) to a source of 5VDC or lower. Measurement of Output Current, Output Voltage and Input Voltage The module is capable of measuring key module parameters such as output current and voltage and input voltage and providing this information through the PMBus interface. Roughly every 200s, the module makes 16 measurements each of output current, voltage and input voltage. Average values of each of these measurements are then calculated and placed in the appropriate registers. These values in the registers can then be read using the PMBus interface. Measuring Output Current Using the PMBus The module measures current by using the inductor winding resistance as a current sense element. The inductor winding resistance is then the current gain factor used to scale the measured voltage into a current reading. This gain factor is the argument of the IOUT_CAL_GAIN command, and consists of two bytes in the linear data format. The exponent uses the upper five bits [7:3] of the high data byte in two-s complement format and is fixed at -15 (decimal). The remaining 11 bits in two's complement binary format represent the mantissa. During manufacture, each module is calibrated by measuring and storing the current gain factor into non-volatile storage. The current measurement accuracy is also improved by each module being calibrated during manufacture with the offset in the current reading. The IOUT_CAL_OFFSET command is used to store and read the current offset. The argument for this command consists of two bytes composed of a 5-bit exponent (fixed at -4d) and a 11-bit mantissa. This command has a resolution of 62.5mA and a range of -4000mA to +3937.5mA. The READ_IOUT command provides module average output current information. This command only supports positive or current sourced from the module. If the converter is sinking current a reading of 0 is provided. The READ_IOUT command returns two bytes of data in the linear data format. The exponent uses the upper five bits [7:3] of the high data byte in two-s complement format and is fixed at - 4 (decimal). The remaining 11 bits in two's complement binary format represent the mantissa with the 11th bit fixed at 0 since only positive numbers are considered valid. Note that the current reading provided by the module is not corrected for temperature. The temperature corrected current reading for module temperature TModule can be estimated using the following equation , = _ + [( - )x. ] where IOUT_CORR is the temperature corrected value of the current measurement, IREAD_OUT is the module current measurement value, TIND is the temperature of the inductor winding on the module. Since it may be difficult to measure (c)2017 General Electric Company. All rights reserved. Page 22 GE Data Sheet 20A Digital MicroDLynxTM: Non-Isolated DC-DC Power Modules 3Vdc -14.4Vdc input; 0.45Vdc to 5.5Vdc output; 20A Output Current TIND, it may be approximated by an estimate of the module temperature. Measuring Output Voltage Using the PMBus The module can provide output voltage information using the READ_VOUT command. The command returns two bytes of data all representing the mantissa while the exponent is fixed at -10 (decimal). During manufacture of the module, offset and gain correction values are written into the non-volatile memory of the module. The command VOUT_CAL_OFFSET can be used to read and/or write the offset (two bytes consisting of a 16-bit mantissa in two's complement format) while the exponent is always fixed at -10 (decimal). The allowed range for this offset correction is -125 to 124mV. The command VOUT_CAL_GAIN can be used to read and/or write the gain correction - two bytes consisting of a five-bit exponent (fixed at -8) and a 11-bit mantissa. The range of this correction factor is -0.125 to +0.121, with a resolution of 0.004. The corrected output voltage reading is then given by: VOUT ( Final ) [VOUT ( Initial ) (1 VOUT _ CAL _ GAIN )] . VOUT _ CAL _ OFFSET Measuring Input Voltage Using the PMBus The module can provide output voltage information using the READ_VIN command. The command returns two bytes of data in the linear format. The upper five bits [7:3] of the high data form the two's complement representation of the exponent which is fixed at -5 (decimal). The remaining 11 bits are used for two's complement representation of the mantissa, with the 11th bit fixed at zero since only positive numbers are valid. During module manufacture, offset and gain correction values are written into the non-volatile memory of the module. The command VIN_CAL_OFFSET can be used to read and/or write the offset - two bytes consisting of a fivebit exponent (fixed at -5) and a11-bit mantissa in two's complement format. The allowed range for this offset correction is -2to 1.968V, and the resolution is 32mV. The command VIN_CAL_GAIN can be used to read and/or write the gain correction - two bytes consisting of a five-bit exponent (fixed at -8) and a 11-bit mantissa. The range of this correction factor is -0.125 to +0.121, with a resolution of 0.004. The corrected output voltage reading is then given by: VIN ( Final ) [VIN ( Initial ) (1 VIN _ CAL _ GAIN )] VIN _ CAL _ OFFSET STATUS_BYTE : Returns one byte of information with a summary of the most critical device faults. Bit Default Flag Position Value 7 X 0 6 OFF 0 5 VOUT Overvoltage 0 4 IOUT Overcurrent 0 3 VIN Undervoltage 0 2 Temperature 0 1 CML (Comm. Memory Fault) 0 0 None of the above 0 STATUS_WORD: Returns two bytes of information with a summary of the module's fault/warning conditions. Low Byte Bit Default Flag Position Value 7 X 0 6 OFF 0 5 VOUT Overvoltage 0 4 IOUT Overcurrent 0 3 VIN Undervoltage 0 2 Temperature 0 1 CML (Comm. Memory Fault) 0 0 None of the above 0 High Byte Bit Position 7 6 5 4 3 2 1 0 Flag VOUT fault or warning IOUT fault or warning X X POWER_GOOD# (is negated) X X X Default Value 0 0 0 0 0 0 0 0 STATUS_VOUT : Returns one byte of information relating to the status of the module's output voltage related faults. Bit Default Flag Position Value 7 VOUT OV Fault 0 6 X 0 5 X 0 4 VOUT UV Fault 0 3 X 0 2 X 0 1 X 0 0 X 0 Reading the Status of the Module using the PMBus The module supports a number of status information commands implemented in PMBus. However, not all features are supported in these commands. A 1 in the bit position indicates the fault that is flagged. September 7, 2017 (c)2017 General Electric Company. All rights reserved. Page 23 GE Data Sheet 20A Digital MicroDLynxTM: Non-Isolated DC-DC Power Modules 3Vdc -14.4Vdc input; 0.45Vdc to 5.5Vdc output; 20A Output Current STATUS_IOUT : Returns one byte of information relating to the status of the module's output voltage related faults. Bit Default Flag Position Value 7 IOUT OC Fault 0 6 X 0 5 IOUT OC Warning 0 4 X 0 3 X 0 2 X 0 1 X 0 0 X 0 Low Byte Bit Position Flag 7:2 1:0 Module Name Reserved Default Value 000010 10 High Byte Bit Position Flag 7:0 1:0 Module Revision Number Manufacturer ID Default Value None 00 STATUS_TEMPERATURE : Returns one byte of information relating to the status of the module's temperature related faults. Bit Default Flag Position Value 7 OT Fault 0 6 OT Warning 0 5 X 0 4 X 0 3 X 0 2 X 0 1 X 0 0 X 0 STATUS_CML : Returns one byte of information relating to the status of the module's communication related faults. Bit Default Flag Position Value 7 Invalid/Unsupported Command 0 6 Invalid/Unsupported Command 0 5 Packet Error Check Failed 0 4 X 0 3 X 0 2 X 0 1 Other Communication Fault 0 0 X 0 MFR_VIN_MIN : Returns minimum input voltage as two data bytes of information in Linear format (upper five bits are exponent - fixed at -2, and lower 11 bits are mantissa in two's complement format - fixed at 12) MFR_VOUT_MIN : Returns minimum output voltage as two data bytes of information in Linear format (upper five bits are exponent - fixed at -10, and lower 11 bits are mantissa in two's complement format - fixed at 614) MFR_SPECIFIC_00: Returns information related to the type of module. Bits [7:2] in the Low Byte indicate the module type (000010 corresponds to the UDT020 series of module). Bits 1:0 in the High Byte are used to indicate the manufacturer ID, with 00 reserved for GE. September 7, 2017 (c)2017 General Electric Company. All rights reserved. Page 24 GE Data Sheet 20A Digital MicroDLynxTM: Non-Isolated DC-DC Power Modules 3Vdc -14.4Vdc input; 0.45Vdc to 5.5Vdc output; 20A Output Current Summary of Supported PMBus Commands Please refer to the PMBus 1.1 specification for more details of these commands. Table 6 Hex Code Command Non-Volatile Memory Storage Brief Description Turn Module on or off. Also used to margin the output voltage 01 OPERATION Format Bit Position Access Function Default Value 7 r/w On 0 6 r X 0 5 r/w 0 Unsigned Binary 4 3 2 r/w r/w r/w Margin 0 0 0 1 r X X 0 r X X Configures the ON/OFF functionality as a combination of analog ON/OFF pin and PMBus commands Format Unsigned Binary Bit Position 7 6 5 4 3 2 1 0 Access r r r r/w r/w r/w r/w r Function X X X pu cmd cpr pol cpa Default Value 0 0 0 1 0 1 1 1 02 ON_OFF_CONFIG 03 CLEAR_FAULTS Clear any fault bits that may have been set, also releases the SMBALERT# signal if the device has been asserting it. 10 WRITE_PROTECT Used to control writing to the module via PMBus. Copies the current register setting in the module whose command code matches the value in the data byte into non-volatile memory (EEPROM) on the module Format Unsigned Binary Bit Position 7 6 5 4 3 2 1 0 Access r/w r/w r/w x x x x x Function bit7 bit6 bit5 X X X X X Default Value 0 0 0 X X X X X Bit5: 0 - Enables all writes as permitted in bit6 or bit7 1 - Disables all writes except the WRITE_PROTECT, OPERATION and ON_OFF_CONFIG (bit 6 and bit7 must be 0) Bit 6: 0 - Enables all writes as permitted in bit5 or bit7 1 - Disables all writes except for the WRITE_PROTECT and OPERATION commands (bit5 and bit7 must be 0) Bit7: 0 - Enables all writes as permitted in bit5 or bit6 1 - Disables all writes except for the WRITE_PROTECT command (bit5 and bit6 must be 0) 11 STORE_DEFAULT_ALL 12 RESTORE_DEFAULT_ALL Restores all current register settings in the module from values in the module non-volatile memory (EEPROM) STORE_DEFAULT_CODE Copies the current register setting in the module whose command code matches the value in the data byte into non-volatile memory (EEPROM) on the module Bit Position 7 6 5 4 3 2 1 0 Access w w w w w w w w Function Command code RESTORE_DEFAULT_CODE Restores the current register setting in the module whose command code matches the value in the data byte from the value in the module non-volatile memory (EEPROM) Bit Position 7 6 5 4 3 2 1 0 Access w w w w w w w w Function Command code VOUT_MODE The module has MODE set to Linear and Exponent set to -10. These values cannot be changed Bit Position 7 6 5 4 3 2 1 0 Access r r r r r r r r Function Mode Exponent Default Value 0 0 0 1 0 1 1 0 13 14 20 September 7, 2017 YES YES Copies all current register settings in the module into non-volatile memory (EEPROM) on the module. Takes about 50ms for the command to execute. (c)2017 General Electric Company. All rights reserved. Page 25 GE Data Sheet 20A Digital MicroDLynxTM: Non-Isolated DC-DC Power Modules 3Vdc -14.4Vdc input; 0.45Vdc to 5.5Vdc output; 20A Output Current Table 6 (continued) Hex Code 22 25 26 29 Command Non-Volatile Memory Storage Brief Description VOUT_TRIM Apply a fixed offset voltage to the output voltage command value Format Linear, two's complement binary Bit Position 7 6 5 4 3 2 1 Access r/w r r/w r/w r/w r/w r/w Function High Byte Default Value 0 0 0 0 0 0 0 Bit Position 7 6 5 4 3 2 1 Access r/w r/w r/w r/w r/w r/w r/w Function Low Byte Default Value 0 0 0 0 0 0 0 VOUT_MARGIN_HIGH Sets the target voltage for margining the output high Format Linear, two's complement binary Bit Position 7 6 5 4 3 2 1 Access r r/w r/w r/w r/w r/w r/w Function High Byte Default Value 0 0 0 0 0 1 0 Bit Position 7 6 5 4 3 2 1 Access r/w r/w r/w r/w r/w r/w r/w Function Low Byte Default Value 0 1 0 0 0 1 1 0 r/w 0 0 r/w YES 0 0 r/w 1 0 r/w YES 1 VOUT_MARGIN_LOW Sets the target voltage for margining the output low Format Linear, two's complement binary Bit Position 7 6 5 4 3 2 1 Access r r/w r/w r/w r/w r/w r/w Function High Byte Default Value 0 0 0 0 0 1 0 Bit Position 7 6 5 4 3 2 1 Access r/w r/w r/w r/w r/w r/w r/w Function Low Byte Default Value 0 1 0 1 0 0 0 VOUT_SCALE_LOOP Sets the scaling of the output voltage - equal to the feedback resistor divider ratio Format Linear, two's complement binary Bit Position 7 6 5 4 3 2 1 0 Access r r r r r r r/w r/w Function Exponent Mantissa Default Value 1 0 1 1 1 0 0 1 Bit Position 7 6 5 4 3 2 1 0 Access r/w r/w r/w r/w r/w r/w r/w r/w Function Mantissa Default Value 0 0 0 0 0 0 0 0 YES Sets the value of input voltage at which the module turns on Format Linear, two's complement binary Bit Position 7 6 5 4 3 2 1 Access r r r r r r r Function Exponent Mantissa Default Value 1 1 1 1 0 0 0 Bit Position 7 6 5 4 3 2 1 Access r r/w r/w r/w r/w r/w r/w Function Mantissa Default Value 0 0 0 0 1 0 1 YES 35 September 7, 2017 VIN_ON (c)2017 General Electric Company. All rights reserved. 0 r/w 0 0 r/w YES 1 0 r 0 0 r/w 1 Page 26 GE Data Sheet 20A Digital MicroDLynxTM: Non-Isolated DC-DC Power Modules 3Vdc -14.4Vdc input; 0.45Vdc to 5.5Vdc output; 20A Output Current Table 6 (continued) Hex Code Command 36 38 39 40 41 VIN_OFF Non-Volatile Memory Storage Brief Description Sets the value of input voltage at which the module turns off Format Linear, two's complement binary Bit Position 7 6 5 4 3 2 1 Access r r r r r r r Function Exponent Mantissa Default Value 1 1 1 1 0 0 0 Bit Position 7 6 5 4 3 2 1 Access r r/w r/w r/w r/w r/w r/w Function Mantissa Default Value 0 0 0 0 1 0 1 0 r 0 0 r/w YES 0 IOUT_CAL_GAIN Returns the value of the gain correction term used to correct the measured output current Format Linear, two's complement binary Bit Position 7 6 5 4 3 2 1 0 Access r r r r r r r r/w Function Exponent Mantissa Default Value 1 0 0 0 1 0 0 V Bit Position 7 6 5 4 3 2 1 0 Access r/w r/w r/w r/w r/w r/w r/w r/w Function Mantissa Default Value V: Variable based on factory calibration YES IOUT_CAL_OFFSET Returns the value of the offset correction term used to correct the measured output current Format Linear, two's complement binary Bit Position 7 6 5 4 3 2 1 0 Access r r r r r r/w r r Function Exponent Mantissa Default Value 1 1 1 0 0 V 0 0 Bit Position 7 6 5 4 3 2 1 0 Access r r r/w r/w r/w r/w r/w r/w Function Mantissa Default Value 0 0 V: Variable based on factory calibration YES VOUT_OV_FAULT_LIMIT Sets the voltage level for an output overvoltage fault. Exponent is fixed at -10. Suggested value shown for 1.2Vo. Should be changed for different output voltage. Values can be 108%, 110%, 112% or 115% of output voltage Format Linear, two's complement binary Bit Position 7 6 5 4 3 2 1 0 Access r r/w r/w r/w r/w r/w r/w r/w Function High Byte Default Value 0 0 0 0 0 1 0 1 Bit Position 7 6 5 4 3 2 1 0 Access r/w r/w r/w r/w r/w r/w r/w r/w Function Low Byte Default Value 0 1 1 0 0 0 0 0 YES VOUT_OV_FAULT_RESPONSE Instructs the module on what action to take in response to a output overvoltage fault Format Unsigned Binary Bit Position 7 6 5 4 3 2 1 0 Access r/w r/w r/w r/w r/w r r r RSP RSP Function RS[2] RS[1] RS[0] X X X [1] [0] Default Value 1 1 1 1 1 1 0 0 YES September 7, 2017 (c)2017 General Electric Company. All rights reserved. Page 27 GE Data Sheet 20A Digital MicroDLynxTM: Non-Isolated DC-DC Power Modules 3Vdc -14.4Vdc input; 0.45Vdc to 5.5Vdc output; 20A Output Current Table 6 (continued) Hex Code 44 45 46 4A 5E Command Brief Description Non-Volatile Memory Storage VOUT_UV_FAULT_LIMIT Sets the voltage level for an output undervoltage fault. Exponent is fixed at -10. Suggested value shown for 1.2Vo. Should be changed for different output voltage. Values can be 92%, 90%, 88% or 85% of output voltage Format Linear, two's complement binary Bit Position 7 6 5 4 3 2 1 0 Access r r/w r/w r/w r/w r/w r/w r/w Function High Byte Default Value 0 0 0 0 0 1 0 0 Bit Position 7 6 5 4 3 2 1 0 Access r/w r/w r/w r/w r/w r/w r/w r/w Function Low Byte Default Value 0 0 1 1 1 0 0 1 YES Instructs the module on what action to take in response to a output undervoltage fault Format Unsigned Binary Bit Position 7 6 5 4 3 2 1 Access r/w r/w r/w r/w r/w r r RSP RSP Function RS[2] RS[1] RS[0] X X [1] [0] Default Value 0 0 0 0 0 1 0 YES VOUT_UV_FAULT_RESPONSE IOUT_OC_FAULT_LIMIT IOUT_OC_WARN_LIMIT POWER_GOOD_ON September 7, 2017 Sets the output overcurrent fault level in A (cannot be changed) Format Linear, two's complement binary Bit Position 7 6 5 4 3 2 1 Access r r r r r r r Function Exponent Mantissa Default Value Bit Position 7 6 5 4 3 2 1 Access r r r r r r r Function Mantissa Default Value 0 0 1 1 0 1 0 Sets the output overcurrent warning level in A Format Linear, two's complement binary Bit Position 7 6 5 4 3 2 1 Access r r r r r r r Function Exponent Mantissa Default Value 1 1 1 1 1 0 0 Bit Position 7 6 5 4 3 2 1 Access r r r/w r/w r/w r/w r/w Function Mantissa Default Value 0 0 1 1 0 0 1 Sets the output voltage level at which the PGOOD pin is asserted high Format Linear, two's complement binary Bit Position 7 6 5 4 3 2 1 Access r r/w r/w r/w r/w r/w r/w Function High Byte Default Value 0 0 0 0 0 1 0 Bit Position 7 6 5 4 3 2 1 Access r/w r/w r/w r/w r/w r/w r/w Function Low Byte Default Value 0 1 1 0 1 0 1 (c)2017 General Electric Company. All rights reserved. 0 r X 0 0 r YES 0 R 0 0 r 0 0 r/w YES 0 0 r/w 0 0 r/w YES 0 Page 28 GE Data Sheet 20A Digital MicroDLynxTM: Non-Isolated DC-DC Power Modules 3Vdc -14.4Vdc input; 0.45Vdc to 5.5Vdc output; 20A Output Current Table 6 (continued) Hex Code 5F Command POWER_GOOD_OFF 61 78 79 7A 7B TON_RISE STATUS_BYTE Non-Volatile Memory Storage Brief Description Sets the output voltage level at which the PGOOD pin is de-asserted low Format Linear, two's complement binary Bit Position 7 6 5 4 3 2 1 0 Access r r/w r/w r/w r/w r/w r/w r/w Function High Byte Default Value 0 0 0 0 0 1 0 0 Bit Position 7 6 5 4 3 2 1 0 Access r/w r/w r/w r/w r/w r/w r/w r/w Function Low Byte Default Value 0 1 0 1 0 0 1 0 YES Sets the rise time of the output voltage during startup Format Linear, two's complement binary Bit Position 7 6 5 4 3 2 1 Access r r r r r r r Function Exponent Mantissa Default Value 1 1 1 0 0 0 0 Bit Position 7 6 5 4 3 2 1 Access r/w r/w r/w r/w r/w r/w r/w Function Mantissa Default Value 0 0 1 0 1 0 1 YES 0 r/w 0 0 r/w 1 Returns one byte of information with a summary of the most critical module faults Format Unsigned Binary Bit Position 7 6 5 4 3 2 1 0 Access r r r r r r r r VOUT IOUT_ VIN_U OTHE Flag X OFF TEMP CML _OV OC V R Default Value 0 0 0 0 0 0 0 0 STATUS_WORD Returns two bytes of information with a summary of the module's fault/warning conditions Format Unsigned binary Bit Position 7 6 5 4 3 2 1 0 Access r r r r r r r r IOUT_ PGOO Flag VOUT X X X X X OC D Default Value 0 0 0 0 0 0 0 0 Bit Position 7 6 5 4 3 2 1 0 Access r r r r r r r r VOUT IOUT_ VIN_U OTHE Flag X OFF TEMP CML _OV OC V R Default Value 0 0 0 0 0 0 0 0 STATUS_VOUT Returns one byte of information with the status of the module's output voltage related faults Format Unsigned Binary Bit Position 7 6 5 4 3 2 1 0 Access r r r r r r r r Flag VOUT_OV X X VOUT_UV X X X X Default Value 0 0 0 0 0 0 0 0 STATUS_IOUT Returns one byte of information with the status of the module's output current related faults Format Unsigned Binary Bit Position 7 6 5 4 3 2 1 0 Access r r r r r r r r Flag IOUT_OC X IOUT_OC_WARN X X X X X Default Value 0 0 0 0 0 0 0 0 September 7, 2017 (c)2017 General Electric Company. All rights reserved. Page 29 GE Data Sheet 20A Digital MicroDLynxTM: Non-Isolated DC-DC Power Modules 3Vdc -14.4Vdc input; 0.45Vdc to 5.5Vdc output; 20A Output Current Table 6 (continued) Hex Code 7D 7E Command STATUS_TEMPERATURE STATUS_CML 88 8B 8C 98 READ_VIN Non-Volatile Memory Storage Brief Description Returns one byte of information with the status of the module's temperature related faults Format Unsigned Binary Bit Position 7 6 5 4 3 2 1 0 Access r r r r r r r r Flag OT_FAULT OT_WARN X X X X X X Default Value 0 0 0 0 0 0 0 0 Returns one byte of information with the status of the module's communication related faults Format Unsigned Binary Bit Position 7 6 5 4 3 2 1 0 Access r r r r r r r r Other Invalid Invalid PEC Flag X X X Comm X Command Data Fail Fault Default Value 0 0 0 0 0 0 0 0 Returns the value of the input voltage applied to the module Format Linear, two's complement binary Bit Position 7 6 5 4 3 2 1 Access r r r r r r r Function Exponent Mantissa Default Value 1 1 0 1 1 0 0 Bit Position 7 6 5 4 3 2 1 Access r r r r r r r Function Mantissa Default Value 0 0 0 0 0 0 0 READ_VOUT Returns the value of the output voltage of the module Format Linear, two's complement binary Bit Position 7 6 5 4 3 2 Access r r r r r r Function Mantissa Default Value 0 0 0 0 0 0 Bit Position 7 6 5 4 3 2 Access r r r r r r Function Mantissa Default Value 0 0 0 0 0 0 READ_IOUT Returns the value of the output current of the module Format Linear, two's complement binary Bit Position 7 6 5 4 3 2 1 Access r r r r r r r Function Exponent Mantissa Default Value 1 1 1 0 0 0 0 Bit Position 7 6 5 4 3 2 1 Access r r r r r r r Function Mantissa Default Value 0 0 0 0 0 0 0 PMBUS_REVISION September 7, 2017 0 r 0 0 r 0 1 r 0 r 0 1 r 0 0 r 0 0 0 r 0 0 r 0 Returns one byte indicating the module is compliant to PMBus Spec. 1.1 (read only) Format Unsigned Binary Bit Position 7 6 5 4 3 2 1 0 Access r r r r r r r r Default Value 0 0 0 1 0 0 0 1 (c)2017 General Electric Company. All rights reserved. YES Page 30 GE Data Sheet 20A Digital MicroDLynxTM: Non-Isolated DC-DC Power Modules 3Vdc -14.4Vdc input; 0.45Vdc to 5.5Vdc output; 20A Output Current Table 6 (continued) Hex Code A0 A4 D0 D4 D5 Command MFR_VIN_MIN MFR_VOUT_MIN MFR_SPECIFIC_00 VOUT_CAL_OFFSET VOUT_CAL_GAIN September 7, 2017 Non-Volatile Memory Storage Brief Description Returns the minimum input voltage the module is specified to operate at (read only) Format Linear, two's complement binary Bit Position 7 6 5 4 3 2 1 0 Access r r r r r r r r Function Exponent Mantissa Default Value 1 1 1 1 0 0 0 0 Bit Position 7 6 5 4 3 2 1 0 Access r r r r r r r r Function Mantissa Default Value 0 0 0 0 1 1 0 0 YES Returns the minimum output voltage possible from the module (read only) Format Linear, two's complement binary Bit Position 7 6 5 4 3 2 1 Access r r r r r r r Function Exponent Mantissa Default Value 0 0 0 0 0 0 1 Bit Position 7 6 5 4 3 2 1 Access r r r r r r r Function Mantissa Default Value 0 1 1 0 0 1 1 YES Returns module name information (read only) Format Unsigned Binary Bit Position 7 6 5 4 3 Access r r r r r Function Reserved Default Value 0 0 0 0 0 Bit Position 7 6 5 4 3 Access r r r r r Function Module Name Default Value 0 0 0 0 1 0 r 0 0 r 0 2 r 1 r 0 2 r 0 0 1 0 r r Reserved 1 0 0 0 r YES Applies an offset to the READ_VOUT command results to calibrate out offset errors in module measurements of the output voltage (between -125mV and +124mV) Format Linear, two's complement binary Bit Position 7 6 5 4 3 2 1 0 Access r/w r r r r r r r Function Mantissa Default Value V 0 0 0 0 0 0 0 Bit Position 7 6 5 4 3 2 1 0 Access r r/w r/w r/w r/w r/w r/w r/w Function Mantissa Default Value V V V V V V V V YES Applies a gain correction to the READ_VOUT command results to calibrate out gain errors in module measurements of the output voltage (between -0.125 and 0.121) Format Linear, two's complement binary Bit Position 7 6 5 4 3 2 1 0 Access r r r r r r/w r r Function Exponent Mantissa Default Value 1 1 0 0 0 0 0 V Bit Position 7 6 5 4 3 2 1 0 Access r r r r/w r/w r/w r/w r/w Function Mantissa Default Value V V V V V V V V YES (c)2017 General Electric Company. All rights reserved. Page 31 GE Data Sheet 20A Digital MicroDLynxTM: Non-Isolated DC-DC Power Modules 3Vdc -14.4Vdc input; 0.45Vdc to 5.5Vdc output; 20A Output Current Table 6 (continued) Hex Code D6 D7 Command VIN_CAL_OFFSET VIN_CAL_GAIN September 7, 2017 Brief Description Non-Volatile Memory Storage Applies an offset correction to the READ_VIN command results to calibrate out offset errors in module measurements of the input voltage (between -2V and +1.968V) Format Linear, two's complement binary Bit Position 7 6 5 4 3 2 1 0 Access r r r r r r r/w r Function Exponent Mantissa Default Value 1 1 0 1 V 0 0 V Bit Position 7 6 5 4 3 2 1 0 Access r r r/w r/w r/w r/w r/w r/w Function Mantissa Default Value 0 0 V V V V V V YES Applies a gain correction to the READ_VIN command results to calibrate out gain errors in module measurements of the input voltage (between -0.125 and 0.121) Format Linear, two's complement binary Bit Position 7 6 5 4 3 2 1 0 Access r r r r r r/w r r Function Exponent Mantissa Default Value 1 1 0 0 V 0 0 V Bit Position 7 6 5 4 3 2 1 0 Access r r r r/w r/w r/w r/w r/w Function Mantissa Default Value 0 0 0 V V V V V YES (c)2017 General Electric Company. All rights reserved. Page 32 GE Data Sheet 20A Digital MicroDLynxTM: Non-Isolated DC-DC Power Modules 3Vdc -14.4Vdc input; 0.45Vdc to 5.5Vdc output; 20A Output Current Thermal Considerations Power modules operate in a variety of thermal environments; however, sufficient cooling should always be provided to help ensure reliable operation. Considerations include ambient temperature, airflow, module power dissipation, and the need for increased reliability. A reduction in the operating temperature of the module will result in an increase in reliability. The thermal data presented here is based on physical measurements taken in a wind tunnel. The test set-up is shown in Figure 48. The preferred airflow direction for the module is in Figure 49. The thermal reference points, Tref used in the specifications are also shown in Figure 49. For reliable operation the temperatures at these points should not exceed 120oC. The output power of the module should not exceed the rated power of the module (Vo,set x Io,max). Please refer to the Application Note "Thermal Characterization Process For Open-Frame BoardMounted Power Modules" for a detailed discussion of thermal aspects including maximum device temperatures. 25.4_ (1.0) Wind Tunnel PWBs Power Module Figure 49. Preferred airflow direction and location of hotspot of the module (Tref). 76.2_ (3.0) x 12.7_ (0.50) Probe Location for measuring airflow and ambient temperature Air flow Figure 48. Thermal Test Setup. September 7, 2017 (c)2017 General Electric Company. All rights reserved. Page 33 GE Data Sheet 20A Digital MicroDLynxTM: Non-Isolated DC-DC Power Modules 3Vdc -14.4Vdc input; 0.45Vdc to 5.5Vdc output; 20A Output Current Shock and Vibration The ruggedized (-D version) of the modules are designed to withstand elevated levels of shock and vibration to be able to operate in harsh environments. The ruggedized modules have been successfully tested to the following conditions: Non operating random vibration: Random vibration tests conducted at 25C, 10 to 2000Hz, for 30 minutes each level, starting from 30Grms (Z axis) and up to 50Grms (Z axis). The units were then subjected to two more tests of 50Grms at 30 minutes each for a total of 90 minutes. Operating shock to 40G per Mil Std. 810F, Method 516.4 Procedure I: The modules were tested in opposing directions along each of three orthogonal axes, with waveform and amplitude of the shock impulse characteristics as follows: All shocks were half sine pulses, 11 milliseconds (ms) in duration in all 3 axes. Units were tested to the Functional Shock Test of MIL-STD-810, Method 516.4, Procedure I - Figure 516.4-4. A shock magnitude of 40G was utilized. The operational units were subjected to three shocks in each direction along three axes for a total of eighteen shocks. Operating vibration per Mil Std 810F, Method 514.5 Procedure I: The ruggedized (-D version) modules are designed and tested to vibration levels as outlined in MIL-STD-810F, Method 514.5, and Procedure 1, using the Power Spectral Density (PSD) profiles as shown in Table 7 and Table 8 for all axes. Full compliance with performance specifications was required during the performance test. No damage was allowed to the module and full compliance to performance specifications was required when the endurance environment was removed. The module was tested per MIL-STD810, Method 514.5, Procedure I, for functional (performance) and endurance random vibration using the performance and endurance levels shown in Table 7 and Table 8 for all axes. The performance test has been split, with one half accomplished before the endurance test and one half after the endurance test (in each axis). The duration of the performance test was at least 16 minutes total per axis and at least 120 minutes total per axis for the endurance test. The endurance test period was 2 hours minimum per axis. Frequency (Hz) 10 30 40 50 90 110 130 140 Frequency (Hz) 10 30 40 50 90 110 130 140 September 7, 2017 Table 7: Performance Vibration Qualification - All Axes PSD Level PSD Level Frequency (Hz) Frequency (Hz) (G2/Hz) (G2/Hz) 1.14E-03 170 2.54E-03 690 5.96E-03 230 3.70E-03 800 9.53E-04 290 7.99E-04 890 2.08E-03 340 1.12E-02 1070 2.08E-03 370 1.12E-02 1240 7.05E-04 430 8.84E-04 1550 5.00E-03 490 1.54E-03 1780 8.20E-04 560 5.62E-04 2000 PSD Level (G2/Hz) 1.03E-03 7.29E-03 1.00E-03 2.67E-03 1.08E-03 2.54E-03 2.88E-03 5.62E-04 Table 8: Endurance Vibration Qualification - All Axes PSD Level PSD Level Frequency (Hz) Frequency (Hz) (G2/Hz) (G2/Hz) 0.00803 170 0.01795 690 0.04216 230 0.02616 800 0.00674 290 0.00565 890 0.01468 340 0.07901 1070 0.01468 370 0.07901 1240 0.00498 430 0.00625 1550 0.03536 490 0.01086 1780 0.0058 560 0.00398 2000 PSD Level (G2/Hz) 0.00727 0.05155 0.00709 0.01887 0.00764 0.01795 0.02035 0.00398 (c)2017 General Electric Company. All rights reserved. Page 34 GE Data Sheet 20A Digital MicroDLynxTM: Non-Isolated DC-DC Power Modules 3Vdc -14.4Vdc input; 0.45Vdc to 5.5Vdc output; 20A Output Current Example Application Circuit Requirements: Vin: 12V Vout: 1.8V Iout: 15A max., worst case load transient is from 10A to 15A Vout: 1.5% of Vout (27mV) for worst case load transient Vin, ripple 1.5% of Vin (180mV, p-p) Vin+ VIN Vout+ VOUT VS+ PGOOD RTUNE MODULE SEQ CTUNE CLK CI3 CI2 CI1 TRIM DATA CO1 CO2 CO3 ADDR0 SMBALRT# RTrim ADDR1 ON/OFF RADDR1 RADDR0 SIG_GND SYNC GND VS- GND CI1 Decoupling cap - 1x0.047F/16V ceramic capacitor (e.g. Murata LLL185R71C473MA01) CI2 3x22F/16V ceramic capacitor (e.g. Murata GRM32ER61C226KE20) CI3 470F/16V bulk electrolytic CO1 Decoupling cap - 1x0.047F/16V ceramic capacitor (e.g. Murata LLL185R71C473MA01) CO2 N.A. CO3 3 x 330F/6.3V Polymer (e.g. Sanyo Poscap) CTune 4700pF ceramic capacitor (can be 1206, 0805 or 0603 size) RTune 330 ohms SMT resistor (can be 1206, 0805 or 0603 size) RTrim 10k SMT resistor (can be 1206, 0805 or 0603 size, recommended tolerance of 0.1%) Note: The DATA, CLK and SMBALRT pins do not have any pull-up resistors inside the module. Typically, the SMBus master controller will have the pull-up resistors as well as provide the driving source for these signals. September 7, 2017 (c)2017 General Electric Company. All rights reserved. Page 35 GE Data Sheet 20A Digital MicroDLynxTM: Non-Isolated DC-DC Power Modules 3Vdc -14.4Vdc input; 0.45Vdc to 5.5Vdc output; 20A Output Current Mechanical Outline Dimensions are in millimeters and (inches). Tolerances: x.x mm 0.5 mm (x.xx in. 0.02 in.) [unless otherwise indicated] x.xx mm 0.25 mm (x.xxx in 0.010 in.) 1 If September 7, 2017 PIN FUNCTION PIN FUNCTION 1 2 3 4 5 6 7 8 9 ON/OFF VIN SEQ GND TRIM VOUT VS+ VSPG 10 11 12 13 14 15 16 SYNC1 CLK DATA SMBALERT# SIG_GND ADDR1 ADDR0 unused, connect to Ground. (c)2017 General Electric Company. All rights reserved. Page 36 GE Data Sheet 20A Digital MicroDLynxTM: Non-Isolated DC-DC Power Modules 3Vdc -14.4Vdc input; 0.45Vdc to 5.5Vdc output; 20A Output Current Recommended Pad Layout Dimensions are in millimeters and (inches). Tolerances: x.x mm 0.5 mm (x.xx in. 0.02 in.) [unless otherwise indicated] x.xx mm 0.25 mm (x.xxx in 0.010 in.) 2 If September 7, 2017 PIN FUNCTION PIN FUNCTION 1 2 3 4 5 6 7 8 9 ON/OFF VIN SEQ GND TRIM VOUT VS+ VSPG 10 11 12 13 14 15 16 SYNC2 CLK DATA SMBALERT# SIG_GND ADDR1 ADDR0 unused, connect to Ground. (c)2017 General Electric Company. All rights reserved. Page 37 GE Data Sheet 20A Digital MicroDLynxTM: Non-Isolated DC-DC Power Modules 3Vdc -14.4Vdc input; 0.45Vdc to 5.5Vdc output; 20A Output Current Packaging Details The 12V Digital MicroDLynxTM 20A modules are supplied in tape & reel as standard. Modules are shipped in quantities of 200 modules per reel. All Dimensions are in millimeters and (in inches). Reel Dimensions: Outside Dimensions: Inside Dimensions: 330.2 mm (13.00) 177.8 mm (7.00") Tape Width: 44.00 mm (1.732") September 7, 2017 (c)2017 General Electric Company. All rights reserved. Page 38 GE Data Sheet 20A Digital MicroDLynxTM: Non-Isolated DC-DC Power Modules 3Vdc -14.4Vdc input; 0.45Vdc to 5.5Vdc output; 20A Output Current Pick and Place The 20A Digital MicroDLynxTM modules use an open frame construction and are designed for a fully automated assembly process. The modules are fitted with a label designed to provide a large surface area for pick and place operations. The label meets all the requirements for surface mount processing, as well as safety standards, and is able to withstand reflow temperatures of up to 300oC. The label also carries product information such as product code, serial number and the location of manufacture. Nozzle Recommendations The module weight has been kept to a minimum by using open frame construction. Variables such as nozzle size, tip style, vacuum pressure and placement speed should be considered to optimize this process. The minimum recommended inside nozzle diameter for reliable operation is 3mm. The maximum nozzle outer diameter, which will safely fit within the allowable component spacing, is 7 mm. Devices). Moisture barrier bags (MBB) with desiccant are required for MSL ratings of 2 or greater. These sealed packages should not be broken until time of use. Once the original package is broken, the floor life of the product at conditions of 30C and 60% relative humidity varies according to the MSL rating (see J-STD-033A). The shelf life for dry packed SMT packages will be a minimum of 12 months from the bag seal date, when stored at the following conditions: < 40 C, < 90% relative humidity. 300 Per J-STD-020 Rev. C Peak Temp 260C 250 Reflow Temp (C) Surface Mount Information 200 * Min. Time Above 235C 15 Seconds 150 Heating Zone 1C/Second Cooling Zone *Time Above 217C 60 Seconds 100 50 0 Reflow Time (Seconds) Bottom Side / First Side Assembly Figure 50. Recommended linear reflow profile using Sn/Ag/Cu solder. This module is not recommended for assembly on the bottom side of a customer board. If such an assembly is attempted, components may fall off the module during the second reflow process. Post Solder Cleaning and Drying Considerations Lead Free Soldering The modules are lead-free (Pb-free) and RoHS compliant and fully compatible in a Pb-free soldering process. Failure to observe the instructions below may result in the failure of or cause damage to the modules and can adversely affect long-term reliability. Post solder cleaning is usually the final circuit-board assembly process prior to electrical board testing. The result of inadequate cleaning and drying can affect both the reliability of a power module and the testability of the finished circuit-board assembly. For guidance on appropriate soldering, cleaning and drying procedures, refer to Board Mounted Power Modules: Soldering and Cleaning Application Note (AN04-001). Pb-free Reflow Profile Power Systems will comply with J-STD-020 Rev. C (Moisture/Reflow Sensitivity Classification for Nonhermetic Solid State Surface Mount Devices) for both Pb-free solder profiles and MSL classification procedures. This standard provides a recommended forced-air-convection reflow profile based on the volume and thickness of the package (table 4-2). The suggested Pb-free solder paste is Sn/Ag/Cu (SAC). For questions regarding Land grid array(LGA) soldering, solder volume; please contact GE for special manufacturing process instructions. The recommended linear reflow profile using Sn/Ag/Cu solder is shown in Fig. 50. Soldering outside of the recommended profile requires testing to verify results and performance. MSL Rating The 20A Digital MicroDLynxTM modules have a MSL rating of 2a. Storage and Handling The recommended storage environment and handling procedures for moisture-sensitive surface mount packages is detailed in J-STD-033 Rev. A (Handling, Packing, Shipping and Use of Moisture/Reflow Sensitive Surface Mount September 7, 2017 (c)2017 General Electric Company. All rights reserved. Page 39 GE Data Sheet 20A Digital MicroDLynxTM: Non-Isolated DC-DC Power Modules 3Vdc -14.4Vdc input; 0.45Vdc to 5.5Vdc output; 20A Output Current Ordering Information Please contact your GE Sales Representative for pricing, availability and optional features. Table 9. Device Codes Device Code Input Voltage Range Output Voltage Output Current On/Off Logic Sequencing Comcodes UDT020A0X3-SRZ 3 - 14.4Vdc 0.45 - 5.5Vdc 20A Negative Yes CC109159728 UDT020A0X3-SRDZ 3 - 14.4Vdc 0.45 - 5.5Vdc 20A Negative Yes CC109168745 UDT020A0X43-SRZ 3 - 14.4Vdc 0.45 - 5.5Vdc 20A Positive Yes CC109159736 -Z refers to RoHS compliant parts Table 10. Coding Scheme Package Identifier Family U P=Pico U=Micro M=Mega G=Giga Sequencing Option Output current Output voltage D T 020A0 X D=Dlynx Digital T=with EZ Sequence 20A V= DLynx Analog. X=without sequencing On/Off logic X= 4= programm positive able output No entry = negative Remote Sense ROHS Compliance Options 3 -SR -D Z 3= Remote Sense S= Surface Mount D = 105C operating ambient, 40G operating shock as per MIL Std 810F Z = ROHS6 R= Tape & Reel GE Digital Non-Isolated DC-DC products use technology licensed from Power-One, protected by US patents: US20040246754, US2004090219A1, US2004093533A1, US2004123164A1, US2004123167A1, US2004178780A1, US2004179382A1, US20050200344, US20050223252, US2005289373A1, US20060061214, US2006015616A1, US20060174145, US20070226526, US20070234095, US20070240000, US20080052551, US20080072080, US20080186006, US6741099, US6788036, US6936999, US6949916, US7000125, US7049798, US7068021, US7080265, US7249267, US7266709, US7315156, US7372682, US7373527, US7394445, US7456617, US7459892, US7493504, US7526660. Outside the US the Power-One licensed technology is protected by patents: AU3287379AA, AU3287437AA, AU3290643AA, AU3291357AA, CN10371856C, CN1045261OC, CN10458656C, CN10459360C, CN10465848C, CN11069332A, CN11124619A, CN11346682A, CN1685299A, CN1685459A, CN1685582A, CN1685583A, CN1698023A, CN1802619A, EP1561156A1, EP1561268A2, EP1576710A1, EP1576711A1, EP1604254A4, EP1604264A4, EP1714369A2, EP1745536A4, EP1769382A4, EP1899789A2, EP1984801A2, W004044718A1, W004045042A3, W004045042C1, W004062061 A1, W004062062A1, W004070780A3, W004084390A3, W004084391A3, W005079227A3, W005081771A3, W006019569A3, W02007001584A3, W02007094935A3 Contact Us For more information, call us at USA/Canada: +1 877 546 3243, or +1 972 244 9288 Asia-Pacific: +86.021.54279977*808 Europe, Middle-East and Africa: +49.89.878067-280 www.gecriticalpower.com GE Critical Power reserves the right to make changes to the product(s) or information contained herein without notice, and no liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. September 7, 2017 (c)2017 General Electric Company. All International rights reserved. Version 2.3